Technical Sepcifications for E896
Beams: 11.6 GeV/nucleon Au April 1998 1.2x10**8 events, 0.8x10**8 central
12 GeV protons September 1998, 6x10**6 events
Sweeper Magnet: 6.2T
Analyzer Magnet: 1.589T
Beam Vector Detectors:
distance between BVD1 and BVD2:
distance from BVD2 to target:
SDDA:
distance from target: 8 cm
detetor planes: 15
acceptance: 0.8.lt.eta(SDDA).lt1.8
opening angle: 20 degrees
Tungsten collimator:
opening angle: 2.7 degrees
DDC:
distance from target: 131 cm
(target at 253 cm, first Z plane at 384 cm)
detector planes: 144
gas: He 50% C2H6 50%
2.0 .lt. y .lt. y(beam)
opening angle: 2.7 degrees
Multiplicity detector:
Exit charge detector:
MultiFunctional Neutron Detector (MUFFINS)
30 slats of 3cm thick scintillator 30cm in diameter, each viewed by 6 PMTs
TIme-Of-Flight detector: